The AI agent for power system studies

It builds the one-line from your drawings, runs the studies in EasyPower and assembles the report package. You check what it flags.

EasyPower 26 · Windows 10 and 11 · ETAP soon

Dazzle Agent· Northgate Plant FilesAgent
EasyPowerEasyPowerNorthgatePlant_Study_Rev0.pdf
Empty one-line UTILITY XFMR-A 1500 kVA13.8 / 0.48 kV SWBD-A 0.48 kV PNL-H1 PNL-D2 TS-A MCC-AGEG-A C-PNL-D2 · length? C-PNL-D2 · length? C-PNL-D2 · 210 ft 38.612 33.418 23.947 17.806 16.431 50/51
Appendix AOne-line
Appendix BShort circuit
Appendix CArc flash
Appendix DDevice evaluation
Arc Flash StudyReport body · R1
PDFNorthgatePlant_Study_Rev0.pdf · 46 pages
AgentEasyPower connected
Build the one-line from E-301 and the feeder schedule. PDFE-301 Single-line.pdf
Thinking
use_skill single-line-diagram-agent
read_file E-301 · 12 sheets
extract_cables.py → 10 cables
build_oneline · 11 buses
save_oneline NorthgatePlant.dez
Built and saved the one-line. Short circuit is ready to run.
  • Review C-PNL-D2: no length on E-301 or the schedule
  • Review EG-A X/R not on the drawings
C-PNL-D2 is 210 ft per the field notes. Update it.
Thinking
read_dez C-PNL-D2
back up NorthgatePlant.dez
edit_dez C-PNL-D2 · length 210 ft
read_dez C-PNL-D2 · verified
Done: C-PNL-D2 is 210 ft. EasyPower recalculated its impedance and I read the file back to check. The previous version is backed up.
Run short circuit and list the five highest bus fault currents.
Thinking
run_command Short Circuit
read results · 3-phase faults
Highest 3-phase bus fault currents:
  1. SWBD-A 38.6 kA
  2. PNL-D2 33.4 kA
  3. MCC-A 23.9 kA
  4. TS-A 17.8 kA
  5. PNL-H1 16.4 kA
Add the CTs and relays from the protection sheets. PDFE-401 Protection.pdf
Thinking
use_skill ct-agent
use_skill relay-agent
read_file E-401 · 3 sheets
build_oneline update · 4 CTs
Added 4 CTs. The main relay (50/51) is listed for entry.
  • Review CT C-class not on the drawings
Prepare the arc flash study report for this project.
Thinking
use_skill report-agent
report.py collect · 14 files
print_study_appendices A–D
report.py build
The package is ready: report body, four appendices and the merged PDF.
  • Review 2 notes in package_review.md

Built for the engineer of record. It never invents a value, shows where every number came from, and lists what you need to check.

Works the program the way you do. Ribbon commands, dialogs and import in your licensed EasyPower. Short circuit, arc flash and load flow, with the results read back.

Shows where every value came from. Each record carries its source sheet and a confidence level, so you know which rows to check first.

Leaves your work alone. It starts its own EasyPower and never takes over the one you have open. Files are backed up before an edit.

What it does. Type what you need. The results land in your project folder.

Build the one-line from the single-line diagram

It reads the drawing sheets and the feeder schedule, binds feeder tags to buses, checks lengths against the printed voltage-drop math, validates the topology (kV mismatches, islands, duplicate IDs) and imports the model into a new, saved one-line with auto-layout.

You type

Build the one-line from the single-line diagram in this project.

You get

  • <project>-Import.csv in EasyPower 26's sectioned import format
  • A saved .dez one-line, zoomed to fit
  • cables.json with each cable's source and confidence
  • review.json: missing lengths, kV changes that need a transformer

Agents. Six available today, four more on the way.

AgentWhat it doesStatus
Single-line diagramBuses and cables from SLDs and feeder schedulesAvailable
CTRatios, counts and locations from callouts and modelsAvailable
RelayFunctions, models and curves from ANSI boxes and setting filesAvailable
GeneratorRatings, connection and voltage from generator calloutsAvailable
ATSTransfer switches and their busesAvailable
Study reportProject folder to issued package, with QA checksAvailable
Panel scheduleCircuit tables from panel schedule sheetsComing
Load calculationNEC Article 220 service and feeder calculationsComing
Study prepUtility, transformer and motor data ready for SC and arc flashComing
Code complianceConductor and OCPD sizing and voltage-drop checksComing

Questions

Does it replace EasyPower?

No. You need EasyPower 26 installed and licensed on the same PC. Dazzle Agent runs it inside its window and operates it; every study is still solved by EasyPower. ETAP support is coming soon.

Do I need an AI account?

No. The AI is included in every plan, so there's nothing else to sign up for or configure.

Where do my project files go?

Everything the agent reads and writes lives in your project folder on your PC. The parts of documents the agent reads, and your messages, are sent to the AI model to be processed. Usage data (who, when, which tools, errors) never includes prompts, answers or file contents.

Can my firm control who uses it?

Yes. The app can require sign-in with your company work account, limited to your organization, assigned users and your email domain. See For firms.

Which software does it work with?

EasyPower 26 today; older versions aren't tested. ETAP is coming soon. It runs on Windows 10 or 11 (64-bit), like the study software itself.

What does it cost?

Plans start at $20 a seat a month (Basic), with Starter ($500), Advanced ($1,000) and Enterprise seats for larger monthly credit budgets. See Pricing.

Try it on your next project

Free to start. Installs in a minute, no admin rights needed.